Key Features of Siemens G120C 7.5KW / 10.0HP Drive
Power Rating: 7.5KW (10.0HP)- Delivers reliable and efficient power control for medium-sized industrial applications
Energy-efficient operation- Adjusts motor speed to match demand, reducing energy consumption and lowering operational costs
Compact and rugged design- Saves valuable space while ensuring durability and long service life in challenging environments
Flexible motor control- Provides precise and smooth control across a wide range of motor-driven applications
Built-in protection features- Includes overload, short-circuit, and overcurrent protection for safe and dependable operation
Easy integration and setup- User-friendly configuration tools simplify installation and enable quick integration into existing automation systems
Phases: 3 AC
Line Voltage: 380–480 V (+10% / –20%)
Line Frequency: 47–63 Hz
Rated Current (LO): 21.50 A
Rated Current (HO): 18.20 A
Phases: 3 AC
Rated Voltage: 400 V (IEC), 480 V (NEC)
Rated Power (LO): 7.50 kW / 10 hp
Rated Power (HO): 5.50 kW / 7.5 hp
Rated Current (LO): 16.5 A
Rated Current (HO): 12.5 A
Rated Current (IN): 17.0 A
Max. Output Current: 25.0 A
Pulse Frequency: 4 kHz
Output Frequency (Vector Control): 0–240 Hz
Output Frequency (V/f Control): 0–550 Hz
150% IL for 3 s
110% IL for 57 s (per 300 s cycle)
200% IH for 3 s
150% IH for 57 s (per 300 s cycle)
Power Factor λ: 0.70–0.85
cos φ: 0.95
Efficiency: 0.97
Sound Pressure Level (1 m): 63 dB
Power Loss: 228 W
Filter (Integrated): Unfiltered
Communication: USS / Modbus RTU
Quantity: 6
Switching level 0→1: 11 V
Switching level 1→0: 5 V
Max Inrush Current: 15 mA
Quantity: 1
Relay Output: 1 (DC 30 V / 0.5 A)
Transistor Output: 1 (DC 30 V / 0.5 A)
Quantity: 1 (Differential)
Resolution: 10-bit
Digital Switching Thresholds:
0→1: 4 V
1→0: 1.6 V
Quantity: 1 (Non-isolated)
Supports: PTC, KTY, Thermo-Click
Accuracy: ±5°C
V/f Control (Linear / Square-law / Parameterizable)
V/f ECO (Linear / Square-law)
Sensorless Vector Control
No sensor-based vector or torque control
Cooling: Integrated fan
Cooling Air Requirement: 0.009 m³/s
Altitude: Up to 1000 m
Operating Temperature: –10 to 40°C
Transport Temperature: –40 to 70°C
Storage Temperature: –25 to 55°C
Max Humidity: 95% (no condensation/icing)
Conductor: 0.15–1.50 mm² (AWG 24–16)
Terminal Type: Plug-in screw
Conductor: 4–6 mm² (AWG 12–10)
Terminal Type: Plug-in screw
Conductor: 4–6 mm² (AWG 12–10)
Terminal Type: Plug-in screw
Conductor: 4–6 mm² (AWG 12–10)
Max Line Length: 15 m
PE Connection: M4 screw on housing
Max Motor Cable Length:
Shielded: 150 m
Unshielded: 150 m
Degree of Protection: IP20 / UL open type
Frame Size: FSB
Net Weight: 2.30 kg
Dimensions (W × H × D): 100 × 196 × 203 mm
| Specification | Details |
|---|---|
| Product Name / Model | 6SL3210-1KE21-7UB1 |
| Voltage | 380 - 480 V |
| Rated current | 21.50 A |
| Rated power | 7.50 kW |
| Cooling | Air cooling using an integrated fan |
| Humidity | 95 % |
| Phases | 3 phases |
| Frequency | 47-63 Hz |
| IP protection | IP20 |
| Operation temperature | -10 - +40 Degree C |
| Dimensions | 100 x 196 x 203 mm |
| Net weight | 2.30 kg |

Price: Â